      2. 上海佳實(shí)DH-9900蛋白儀的近紅外分析算法解析

        發(fā)布時(shí)間:2024-09-14
        上海佳實(shí)dh-9900蛋白儀的近紅外分析算法解析
        上海佳實(shí)電子科技有限公司研制的dh-9900蛋白檢測(cè)系統(tǒng)的軟件分析系統(tǒng)具有自學(xué)習(xí)的能力。
        近紅外(nir)檢測(cè)的優(yōu)點(diǎn):樣品無需預(yù)處理,近紅外區(qū)內(nèi)光穿透深度大,使得近紅外光譜技術(shù)可以用漫反射技術(shù)對(duì)樣品直接測(cè)定,同時(shí)還具有分析具有非破壞性、分析速度快、遠(yuǎn)距離測(cè)定和實(shí)時(shí)分析、測(cè)定重現(xiàn)性好、適用的樣品范圍廣、分析成本較低、對(duì)操作人員的要求較低。簡(jiǎn)而言之,使用方便,無需培訓(xùn)。
        nir用于物質(zhì)成份的定量測(cè)定時(shí),譜帶較寬并且容易重疊,需要有化學(xué)計(jì)量學(xué)方法進(jìn)行分析(主成分分析pca、主成分回歸pcr、多元線性回歸、偏小二乘法pls、ann),應(yīng)用多的為pca、pls。
        dh-9900蛋白測(cè)量?jī)x采用的算法是pca和pls,目前,上海佳實(shí)研發(fā)部的軟件工程師正在設(shè)計(jì)多的測(cè)量算法如pcr, ann等以升儀器,提。
        測(cè)定固體樣品的nir光譜時(shí),一般要測(cè)定樣品不同面的光譜以減少測(cè)定誤差并獲得可靠的信息,有時(shí)可以進(jìn)行光譜的重復(fù)測(cè)定以提光譜圖的信噪比。在得到nir光譜圖后,一般還需要對(duì)光譜進(jìn)行預(yù)處理(基線校正、一階導(dǎo)數(shù)、二階導(dǎo)數(shù)和正交信號(hào)校正)。
        感謝廣大客戶的信賴和支持!
        analysis of near infrared analysis algorithm of shanghai jiashi dh-9900 protein meter
        the software analysis system of dh-9900 protein detection system developed by shanghai jiashi electronic technology co., ltd. has self-learning ability.
        advantages of near infrared (nir) detection: the sample does not require pretreatment, and the depth of light penetration in the near-infrared region is large, so that near-infrared spectroscopy can directly measure the sample by diffuse reflection technology, and also has non-destructive analysis and analysis. fast, long-distance measurement and real-time analysis, good reproducibility, wide range of applicable samples, low cost of analysis, and low operator requirements.
        when nir is used for the quantitative determination of material components, the bands are wide and easy to overlap, and chemometric methods are needed for analysis (principal component analysis pca, principal component regression pcr, multiple linear regression, partial least squares pls, ann). the most widely used are pca and pls.
        the algorithms used in the dh-9900 protein meter are pca and pls. currently, software engineers in the r&d department are developing more measurement algorithms such as pcr, ann, etc. to upgrade the instrument and improve accuracy.
        when measuring the nir spectrum of a solid sample, it is common to measure the spectrum of different faces of the sample to reduce the measurement error and obtain reliable information. sometimes, the repeated measurement of the spectrum can be performed to improve the signal-to-noise ratio of the spectrum. after obtaining the nir spectrum, it is generally necessary to preprocess the spectrum (baseline correction, first derivative, second derivative and quadrature signal correction).
        thank you for your trust and support!
        上一個(gè):旋轉(zhuǎn)蒸發(fā)器和旋轉(zhuǎn)蒸發(fā)儀是一樣的么
        下一個(gè):真空干燥箱可能會(huì)發(fā)生爆炸的原因

        外觀專利無效申請(qǐng)?jiān)趺醋?/a>
        建筑地面工程施工質(zhì)量檢驗(yàn)的每檢驗(yàn)批的抽查數(shù)量怎樣確定?
        數(shù)控龍門銑床的刀具角度選擇分析
        危險(xiǎn)的原始林森里面的珍稀普洱茶產(chǎn)區(qū)
        旋轉(zhuǎn)蒸發(fā)儀的使用手冊(cè)
        平板電腦怎么選好(2020年平板電腦怎么選)
        現(xiàn)在登記結(jié)婚需要什么證件
        如何選擇服裝防盜扣
        虎林醫(yī)院污水處理設(shè)備全封閉設(shè)計(jì)
        高智能食品安全檢測(cè)儀價(jià)格